Operating Manual
STXL Advanced Series
CCD Cameras
Santa Barbara Instrument Group
150 Castilian Drive, Suite 101
Santa Barbara, CA 93117
(805) 571-7244 www.sbig.com sbig@sbig.com
Page view 0
1 2 3 4 5 6 ... 32 33

Summary of Contents

Page 1 - Santa Barbara, CA 93117

Operating Manual STXL Advanced Series CCD Cameras Santa Barbara Instrument Group 150 Castilian Drive, Suite 101 Santa Barbara, CA 93117 (

Page 2

operate reliably under full cooling power as the STL supply does not provide the required current for the STXL camera. If you wish to make a custom p

Page 3 - TABLE OF CONTENTS

1.5. Attaching the camera to a telescope. Due to the size of the largest CCD supported by the STXL camera, typical t-threads and even a 2” nosepiece

Page 4

1.8. Connecting water hoses STXL Series cameras are equipped with a heat exchanger that allows water circulation if conditions require additional co

Page 5

1.10. Opening the Front Cover - Regenerating the Desiccant Plug The CCD is housed in a sealed chamber located inside the front cover of the camera.

Page 6

voltage at the camera drops to 10.25V or less. At 10.25V or less, the camera will automatically shut down the TE cooling but otherwise continue to op

Page 7

the jumpers are not on the top board, so it may be easier for this procedure to unplug the fan wiring harness from the digital board to get the wires

Page 8

1.15. Camera Resolution Resolution comes in two flavors these days. In the commercial world of digital devices, the word resolution is often used

Page 9

note that cameras with smaller pixels may be binned 2x2 or 3x3 to create larger pixels and expand the useful range of the camera. For example, an STX

Page 10

36.8 = 4,979 divided by 30 = 166 arcminutes. The table above shows the calculated field of view in arcminutes for each of the several large format

Page 11

2.0. CAMERA SOFTWARE This section gets you up and running right away with your STXL camera. First you’ll install the Application Software and Driv

Page 12

DECLARATION OF CONFORMITY We, Santa Barbara Instrument Group, a division of Aplegen, Inc., 150 Castilian Drive, Santa Barbara, CA

Page 13

Download the latest Drivers from our web site then click the Update button a 2nd time. Your versions may be different than those shown.

Page 14

2.2. Using the Camera This section gives you a quick introduction to using your Camera with CCDOps. Further information can be found in the CCDOps M

Page 15

you’ll see numerous bright or Hot Pixels. You’ll probably see some Hot Pixels with tails below them. These are in every CCD camera and repeat from i

Page 16

Making the Autoguiding Connection Like all SBIG cameras, the STXL has an Autoguider port that can be connected to your Telescope. Use the supplied 6-

Page 17

Appendix A – Adjustments and Maintenance This section describes the various adjustments and maintenance issues with the STXL. Firmware Updates The STX

Page 18

you need to capture images, reduce your cooling to the zero degree C range - the CCD dark current will still be quite low. Cleaning the CCD and the Wi

Page 19

Appendix B - Capturing a Good Flat Field This appendix describes how to take a simple flat field. A good flat field is essential for displaying feat

Page 20

Appendix C – Camera Specifications All STXL Cameras have the following specifications: Power Requirements Input Voltage 10.5 – 14 Volts DC with In

Page 21

Appendix D – Connector and Cables Power Jack The Power Jack has the following pinouts: Pi n Functi on Sh el l Ear th/ Chassi s Gr ou n d 1,5,6 +12V

Page 22

Appendix E – Mechanical Drawings and Backfocus Distances Adapter ring drawings and thread specifications 29

Page 23

TABLE OF CONTENTS 1.0. CAMERA HARDWARE ... 5 1.

Page 24

Backfocus: Camera without filter wheel. 30

Page 25

Backfocus: Camera with Standard Filter Wheel. 31

Page 26

Backfocus: Camera with Self-Guiding Filter Wheel 32

Page 28

Appendix A – Adjustments and Maintenance ... 24 Firmware Updates ...

Page 29

1.0. CAMERA HARDWARE Congratulations and thank you for buying one of Santa Barbara Instrument Group's STXL Series CCD cameras. These large fo

Page 30

Standard Equipment for STXL Series Cameras: STXL Camera Universal Power Supply Regional AC Cord and Plug Power Cable Extension 15’ USB Cable

Page 31

Power Supply Extension Cable This cable extends the distance the power supply may be placed away from the camera. It is also much more flexible than

Page 32

filter wheel for convenience when imaging through narrow band filters or anytime you wish to use an external guider. Canon EOS Lens Adapter This ada

Page 33

1.4. Connectors Remote Guide Head Port This miniature connector is for attaching an optional remote guiding head or the FW8G-STXL Self-Guiding fi